The Air Dome Structure Is Safer Than You Think

Air dome construction has been rapidly developed in my country in recent years, and has been well applied in environmental protection industries such as sports, industry, and commerce.

Get Started >

Air dome structure has been rapidly developed in my country in recent years, and has been well applied in environmental protection industries such as sports, industry, and commerce. But there is also such a voice, whether the air film building is unsafe, it looks like a balloon, will it easily collapse and leak air, here I want to say that the air film building is safer than you think.

1. The air-dome foundation adopts reinforced concrete foundation, whose size, depth and reinforcement have been carefully calculated according to the actual site requirements, so as to ensure the firmness of the foundation.

2. The membrane body of the air film is made of high-strength fiber cloth and polymer materials, which has strong toughness and stretchability, and is strong enough. Generally, sharp objects are not easily damaged by piercing, scratching, or cutting.

3. The air-bearing membrane structure relies on the difference of internal and external air pressure to support the entire building. There are no internal bending, torsion and compression components. It has unparalleled advantages in wind resistance and seismic resistance, and has excellent advantages in other structural systems. safety.

4. Equipped with an intelligent control system. When encountering bad weather, the control system will adjust the air pressure difference according to the feedback signal of the anemometer or snow load meter to maintain the stability of the building. When the grid stops supplying power, the backup generator can also ensure the normal operation of the building. The intelligent control system comes with an automatic early warning function. When there is a special situation in the venue equipment, an alarm message will be automatically generated so that the staff on duty can deal with it in time.

5. The membrane material used in the air film is a non-combustible material, and the fire performance of the membrane material meets the standard. The air film building will design fire emergency doors for emergency personnel to enter and exit. The number of emergency doors depends on the scale of the venue. The fire emergency door adopts steel door frame and aluminum door panel, which has sufficient rigidity. The door leaf is equipped with shutters and emergency lighting to ensure that it can be observed at any time in emergencies.

  • ENVIRONMENTAL FACILITIES

  • COMMERCIAL FACILITIES

  • AIR DOME STRUCTURES

  • TRANSPORTATION AND TRAFFIC FAC

  • ATHLETIC AND SPORTS FACILITIES

  • LANDSCAPE AND SHADE STRUCTURES

From the Learning Center